生活環境研究部
茂呂田 孝一 MOROTA Koichi
専門分野
産業衛生学、放射線衛生学、医療安全管理学
人材育成
専門課程
・保健福祉行政管理分野ー分割前期(基礎)
必修項目「放射線衛生」担当者
・地域医療安全管理専攻科
短期研修
1 医療放射線の適正管理に関する研修 副主任
2 建築物衛生研修 副主任
研究実績
原著論文
1 Hijikata Y, Yamashita K, Hatsusaka N, Nagata T, Kitamura H, Morota K, Matsuzaki S, Nakagami K, Hitomi G, Kuriyama T, Kowatari M, Chida K, Sasaki H, Moritake T. Prevalence of Cataractous Changes in the Eyes and Chronic Inflammatory Changes in the Hands Among Spine Surgeons. Journal of Bone and Joint Surgery. 2025 Feb 107(7) e25-e25 doi: 10.2106/jbjs.24.00433.
2 Kuriyama T, Moritake T, Nakagami K, Morota K, Hitomi G, Kitamura H. Background Factors Affecting the Radiation Exposure of the Lens of the Eye among Nurses in Interventional Radiology: A Quantitative Observational Study. Nursing reports. 2024 Feb 14(1) 413-427. doi: 10.3390/nursrep14010032.
3 Hijikata Y, Kotani Y, Suzuki A, Morota M, Funao H, Miyagi M, Morimoto T, Kanno H, Ishii K. Protective Attitudes toward Occupational Radiation Exposure among Spine Surgeons in Japan: An Epidemiological Description from the Survey by the Society for Minimally Invasive Spinal Treatment. Medicina 2023 May 59(3) 545-545. doi: 10.3390/medicina59030545.
4 Matsuzaki S, Moritake T, Sun L, Morota K, Nagamoto K, Nakagami K, Kuriyama T, Hitomi G, Kajiki S, Kunugita N. The Effect of Pre-Operative Verbal Confirmation for Interventional Radiology Physicians on Their Use of Personal Dosimeters and Personal Protective Equipment. International Journal of Environmental Research and Public Health. 2022 Dec 19(24) 16825-16825. doi: 10.3390/ijerph192416825.
5 Matsuzaki S, Moritake T, Morota M, Nagamoto K, Nakagami K, Kuriyama T, Kunugita N. Development and assessment of an educational application for the proper use of ceiling-suspended radiation shielding screens in angiography rooms using augmented reality technology. European journal of radiology. 2021 Oct 143 109925-109925. doi: 10.1016/j.ejrad.2021.10992.
6 Nakagami K, Moritake T, Nagamoto K, Morota K, Matsuzaki S, Kuriyama T, Kunugita N. Strategy to Reduce the Collective Equivalent Dose for the Lens of the Physician’s Eye Using Short Radiation Protection Curtains to Prevent Cataracts. Diagnostics 2021 Aug 11(8) 1415. doi: 10.3390/diagnostics110814.
7 Morota K, Moritake T, Nagamoto K, Matsuzaki S, Nakagami K, Sun L, Kunugita N. Optimization of the Maximum Skin Dose Measurement Technique Using Digital Imaging and Communication in Medicine-Radiation Dose Structured Report Data for Patients Undergoing Cerebral Angiography. Diagnostics 2020 Dec 11(1) 14. doi: 10.3390/diagnostics110100.
総説
1 盛武敬, 茂呂田孝一, 人見剛. 実測法と推定法による脳血管内治療患者の被ばく線量評価: 生物学的線量反応関係解明への応用可能性. 放射線生物研究会機関誌. 2017; 52: 385-401.
著書
1 佐藤幸光, 東村享治, 茂呂田孝一. 放射線技術学シリーズ 「医療安全管理学 改訂2版」. オーム社 2024. (担当:分担執筆, 範囲:第1章 医療安全の基礎の「1・3・12 医療機関及び放射線部門の災害マニュアル」, 「1・3・13 災害医療の行動指針」, 「 災害医療とメンタルヘルス」 P82-88 第7章 放射線機器等の安全管理の「7・3 医療機器の保守点検」, 「7・4 保守点検結果・記録の保管と管理」, 「7・5 放射線機器導入時・更新時の安全管理」 P359-369).
2 茂呂田孝一, 欅田尚樹. (担当:分担執筆, 血管撮影における線量管理の実際と被ばく実態調査とこれからP62-68) 労災疾病臨床研究事業費補令和3年度総括・分担研究年度終了報告書不均等被ばくを伴う放射線業務における被ばく線量の実態調査と線量低減に向けた課題評価に関する研究 2022.
その他(受賞歴等)
・Best Poster 2nd Place, Evaluation of Trend and Reducing Patient Exposure Dose with DICOM-RDSR, AOCRP5 2018. (Melbourne)